This Code prescribes minimum design and construction requirements for energy efficiency of building envelopes of new buildings and additions to buildings. It applies to buildings having concrete walls, roofs, or floors; masonry walls; and masonry veneer, including veneer attached to frame walls as part of the building envelope. It also provides minimum thermal properties for these assemblies for code compliance. This Code is applicable to low-rise residential buildings that use either electricity from any generation source or fossil fuel. It can be used with applicable energy codes and standards such as the International Energy Conservation Code (IECC).
This Code prescribes minimum design and construction requirements for energy efficiency of building envelopes of new buildings and additions to buildings. It applies to buildings having concrete walls, roofs, or floors; masonry walls; and masonry veneer, including veneer attached to frame walls as part of the building envelope. It also provides minimum thermal properties for these assemblies for code compliance.
This Code is applicable to commercial and mid- to high-rise residential buildings that use either electricity from any generation source or fossil fuel. It can be used with applicable energy codes and standards such as ASHRAE 90.1 and the International Energy Conservation Code (IECC).
Assessment and Retrofit of Masonry Structures provides background, reference material, and guidance to design professionals, building owners, and contractors confronted with addressing existing masonry construction. Information related to construction characteristics, typical material properties, and analytical approaches are included for historic, transitional, and modern masonry construction typologies. The main focus of the book is structural stabilization, strengthening, and retrofit with maintenance and serviceability items (such as water penetration and cleaning) addressed as subtopics.
These masonry course notes were developed for use in semester‐long, undergraduate or combined undergraduate/graduate courses in masonry design. The notes serve as a textbook for structural design classes or could be used to supplement critical topics in construction management courses.
The Masonry Designers’ Guide – 2022 (MDG-2022) is a valuable reference for engineers, contractors, architects, inspectors, building code authorities, and educators. Initial chapters address materials, testing, quality assurance, quality control, and construction methods with reference to specific provisions of the 2022 TMS 402 Code and TMS 602 Specification. Subsequent chapters illustrate fundamental design concepts and demonstrate how to apply Code provisions to structural design of common masonry members. The MDG-2022 also includes discussion on masonry provisions in the 2024 International Building Code (IBC) and its examples are based on ASCE /SEI 7-22.
More than 150 design examples included discuss concrete and clay masonry, autoclaved aerated concrete (AAC) masonry, prestressed masonry, glass unit masonry and more. The final three chapters of the book include 60+ comprehensive design examples for three common masonry buildings (Chapters 19-21).
Ordering either MDG-2022 hard copy option provides free digital access to the MDG-2022 when purchased in the same order (the discount will be applied after adding both items to your cart).
Key updates and revisions incorporated by the Committee include:
Updates for coordination with other reference standards including updates to reflect changes in ASTM standards and reference to the 2022 edition of ASCE/SEI 7.
General cleanup and clarification of provisions and expanded commentary.
Introduced new deflection limits of l/600 for cast stone subjected to out-of-plane loads.
Removed the historical drying shrinkage limit of 0.000325, replaced by a requirement that drying shrinkage be tested and reported.
Minimum thickness requirement of 2.5 inches (64 mm) for all cast stone units.
Permitting the use of glass fiber reinforced polymer bars meeting ASTM D7957/C7957M.
Minimum qualifications for testing labs and inspection agencies are required to be defined.
Standards for Architectural Cast Stone contains three standards and their commentaries:
Standard for Design of Architectural Cast Stone (TMS 404)
Standard for Fabrication of Architectural Cast Stone (TMS 504)
Standard Specification for Installation of Architectural Cast Stone (TMS 604)
Key updates and revisions incorporated by the Committee include:
Updates for coordination with other reference standards including updates to reflect changes in ASTM standards and reference to the 2022 edition of ASCE/SEI 7.
General cleanup and clarification of provisions and expanded commentary.
Introduced new deflection limits of l/600 for cast stone subjected to out-of-plane loads.
Removed the historical drying shrinkage limit of 0.000325, replaced by a requirement that drying shrinkage be tested and reported.
Minimum thickness requirement of 2.5 inches (64 mm) for all cast stone units.
Permitting the use of glass fiber reinforced polymer bars meeting ASTM D7957/C7957M.
Minimum qualifications for testing labs and inspection agencies are required to be defined
The TMS 302 Sound Standard provides minimum requirements for rating masonry walls for sound transmission class (STC) and outdoor-indoor transmission class (OITC) based on testing calibrated calculation procedures.
Topics covered include reference standards, definitions and notations, materials, construction, and methods to STC and OITC rating for concrete masonry and clay masonry assemblies.
TMS 302-18 is adopted by reference in the 2021 International Building Code.
Available through Masonry Standards Online thanks to the support of
TMS 402/602-22 Building Code Requirements and Specification for Masonry Structures contains two standards and their commentaries: Building Code Requirements for Masonry Structures (TMS 402-22) and Specification for Masonry Structures (TMS 602-22). The Code (TMS 402) covers the design and construction of masonry structures while the Specification (TMS 602) is concerned with minimum construction requirements for masonry in structures.
The new 2022 edition has been updated throughout for new referenced standards, including ASCE/SEI 7-22 and numerous ASTM Standards. Other major changes to the TMS 402/602-22 include:
New, more rational, masonry veneer provisions
New Appendix D on composite reinforcement in masonry
Updated and refined provisions throughout, including compression-controlled section requirements
*This file includes errata through September 22, 2022.
Bundle a TMS 402/602 hard copy with the download version to receive a 40% discount on the download (the discount will be applied after adding both items to your cart).
Online Subscription Access
Available online with improved features (copy, print, highlight, annotate, and more) plus more multi-user flexibility through Masonry Standards Online.
TMS Members – 50% off all subscriptions + multi-user discounts Non-Members – 40% off an annual subscription by adding it to your cart along with a hard copy or download
Bundle a TMS 402/602 hard copy with the download version to receive a 40% discount on the download (the discount will be applied after adding both items to your cart).
This guide reports data on the thermal properties of concrete and masonry constituents, masonry units, and systems of materials and products that form building components. This guide includes consideration of thermal inertia of concrete and masonry, passive solar design, and procedures to limit condensation within assemblages.
This code prescribes minimum design and construction requirements for mitigating thermal bridges in the building envelopes of new buildings and additions to existing buildings. It applies to buildings having concrete or masonry walls; masonry veneer, including veneer attached to frame walls; and balconies or components that extend through the building envelope. It also has criteria for metal thermal bridges in these buildings.
This code is applicable to commercial and mid- to high-rise residential buildings that use either electricity or fossil fuel (regardless of the generation source). It can be used with applicable energy codes and standards.
Thank you for your interest in becoming a financial sponsor of the 14th North American Masonry Conference! Sponsorship is very important to ensure the success of the conference and to provide an enjoyable and comfortable forum for the attendees.
Fire resistance of building elements is an important consideration in building design. While structural design considerations for concrete and masonry at ambient temperature conditions are addressed by ACI 318 and TMS 402/ACI 530/ASCE 5, respectively, these codes do not consider the impact of fire on concrete and masonry construction. This standard contains design and analytical procedures for determining the fire resistance of concrete and masonry members and building assemblies. Where differences occur in specific design requirements between this standard and ACI 318 and TMS 402/ACI 530/ASCE 5, as in the case of cover protection of steel reinforcement, the more stringent of the requirements shall apply.
The Building Information Modeling for Masonry Initiative has created this guide to provide architects, engineers, and mason contractors with tools for developing Autodesk Revit models for modeling masonry buildings. Industry experts from CAD Technology Center (CTC) and Integrus Architecture developed building models and narratives that summarize their work and experience