ACI-TMS CODE 122.1-21 Thermal Bridge Mitigation for Buildings Having Concrete and Masonry Walls and Masonry Veneer — Download Version

$99.00

This code prescribes minimum design and construction requirements for mitigating thermal bridges in the building envelopes of new buildings and additions to existing buildings. It applies to buildings having concrete or masonry walls; masonry veneer, including veneer attached to frame walls; and balconies or components that extend through the building envelope. It also has criteria for metal thermal bridges in these buildings.

This code is applicable to commercial and mid- to high-rise residential buildings that use either electricity or fossil fuel (regardless of the generation source). It can be used with applicable energy codes and standards.

This protected download cannot be printed.

This product provides single-user access only and the document license will be linked to the user account that makes the purchase. Please review the restrictions below before purchasing. For multi-user access, visit the vendors on this page. Contact tmsaccountant@masonrysociety.org if you have any questions.
This product is provided as a secure PDC file, which can only be opened using Locklizard Safeguard Viewer. Other PDF Viewers will not be able to read this file. This document can only be opened by a single user and cannot be printedRead more about these limitations here.
This product has a discount of $24.75 for TMS members!
Become a member by purchasing a Masonry Society Membership, renewing your Dues, or log in if you are a member.

SKU: LLF-1|123 Categories: ,

Description

This code prescribes minimum design and construction requirements for mitigating thermal bridges in the building envelopes of new buildings and additions to existing buildings. It applies to buildings having concrete or masonry walls; masonry veneer, including veneer attached to frame walls; and balconies or components that extend through the building envelope. It also has criteria for metal thermal bridges in these buildings.

This code is applicable to commercial and mid- to high-rise residential buildings that use either electricity or fossil fuel (regardless of the generation source). It can be used with applicable energy codes and standards.


TABLE OF CONTENTS

PREFACE, p. 1

CHAPTER 1—GENERAL, p. 3

1.1—Scope, p. 3

1.2—General, p. 3

1.3—Purpose, p. 4

CHAPTER 2—DEFINITIONS, p. 5

2.1—, p. 5

CHAPTER 3—REFERENCED STANDARDS, p. 6

CHAPTER 4—GENERAL REQUIREMENTS, p. 7

4.1—Climate zones, p. 7

4.2—Mitigation of thermal bridges, p. 7

4.3—U-factors for assemblies containing thermal bridges, p. 8

CHAPTER 5—PRESCRIPTIVE METHOD, p. 9

5.1—Building envelope walls extending above the roof insulation, p. 9

5.2—Balconies and projections, p. 10

5.3—Shelf angles supporting masonry veneer, p. 11

5.4—Other thermal bridges, p. 11

CHAPTER 6—BUILDING ENVELOPE TRADE-OFF METHOD, p. 13

6.1—Building envelope trade-off method, p. 13

CHAPTER 7—WHOLE BUILDING SIMULATION METHOD, p. 14

7.1—Whole building simulation method, p. 14

REFERENCES, p. 15

Authored documents, p. 15

APPENDIX—CLIMATE ZONE MAPS FOR USE WITH THE IECC AND ASHRAE/IES 90.1, p. 16