216.1-14 Code Requirements for Determining Fire Resistance of Concrete and Masonry Construction Assemblies – Download Version

$71.50

Fire resistance of building elements is an important consideration in building design. While structural design considerations for concrete and masonry at ambient temperature conditions are addressed by ACI 318 and TMS 402/ACI 530/ASCE 5, respectively, these codes do not consider the impact of fire on concrete and masonry construction. This standard contains design and analytical procedures for determining the fire resistance of concrete and masonry members and building assemblies. Where differences occur in specific design requirements between this standard and ACI 318 and TMS 402/ACI 530/ASCE 5, as in the case of cover protection of steel reinforcement, the more stringent of the requirements shall apply.

This protected download cannot be printed.

Other Available Formats


This product provides single-user access only and the document license will be linked to the user account that makes the purchase. Please review the restrictions below before purchasing. For multi-user access, visit the vendors on this page. Contact tmsaccountant@masonrysociety.org if you have any questions.
This product is provided as a secure PDC file, which can only be opened using Locklizard Safeguard Viewer. Other PDF Viewers will not be able to read this file. This document can only be opened by a single user and cannot be printedRead more about these limitations here.
This product has a member discount of $17.88!
Become a member by purchasing a Masonry Society Membership, renewing your Dues, or log in if you are a member.

SKU: LLF-1|66 Categories: ,

Description

Fire resistance of building elements is an important consideration in building design. While structural design considerations for concrete and masonry at ambient temperature conditions are addressed by ACI 318 and TMS 402/ACI 530/ASCE 5, respectively, these codes do not consider the impact of fire on concrete and masonry construction. This standard contains design and analytical procedures for determining the fire resistance of concrete and masonry members and building assemblies. Where differences occur in specific design requirements between this standard and ACI 318 and TMS 402/ACI 530/ASCE 5, as in the case of cover protection of steel reinforcement, the more stringent of the requirements shall apply.

Keywords: beams; columns; compressive strength; concrete slabs; fire endurance; fire ratings; fire resistance; fire tests; masonry walls; modulus of elasticity; prestressed concrete; prestressing steels; reinforced concrete; reinforcing steel; structural design; temperature distribution; thermal properties; walls.


Table of Contents

CHAPTER 1—GENERAL

1.1—Scope

1.2—Alternative methods

CHAPTER 2—NOTATION AND DEFINITIONS

2.1—Notation

2.2—Definitions

CHAPTER 3—REFERENCED STANDARDS

CHAPTER 4—CONCRETE

4.1—General

4.2—Concrete walls, floors, and roofs

4.3—Concrete cover protection of steel reinforcement

4.4—Analytical methods for calculating structural fire resistance and cover protection of concrete flexural members

4.5—Reinforced concrete columns

4.6—Structural steel columns protected by concrete

4.7—Hollow structural steel columns filled with concrete

CHAPTER 5—CONCRETE MASONRY

5.1—General

5.2—Equivalent thickness

5.3—Concrete masonry wall assemblies

5.4—Reinforced concrete masonry columns

5.5—Reinforced concrete masonry lintels

5.6—Structural steel columns protected by concrete masonry

CHAPTER 6—CLAY BRICK AND TILE MASONRY

6.1—General

6.2—Equivalent thickness

6.3—Clay brick and tile masonry wall assemblies

6.4—Reinforced clay masonry columns

6.5—Reinforced clay masonry lintels

6.6—Expansion or contraction joints

6.7—Structural steel columns protected by clay masonry

CHAPTER 7—EFFECTS OF FINISH MATERIALS ON FIRE RESISTANCE

7.1—General

7.2—Calculation procedure

7.3—Installation of finishes

Additional information

ISBN

9780870319549

Publisher

Joint ACI/TMS Committee 216

Publication Year

2014

Pages

28

Size

6 MB

DRM

Locklizard

License

Single User

Print Restriction

Not Printable